With the GX320 3MP monitor an entire chest CR can be displayed, offering highly refined rendering of extremely delicate grayscale shadings. A built-in swing sensor conveniently appears only when remote quality control operations such as calibration are being performed.
DICOM Part 14 Compliant
To ensure the most accurate and consistent shadings possible, EIZO carefully measures and sets every grayscale tones on the production line to produce a monitor compliant with DICOM Part 14.
DICOM Part 14 Calibration
When the self-diagnosis function, utilized with bundled RadiCS LE quality control software, detects a change in luminance, a warning icon appears on the desktop taskbar enabling prompt correction. Furthermore, the self-calibration function (patent pending), a simplified calibration compliant with the DICOM Part 14 standard, can periodically be performed to correct the grayscale tones and brightness of the monitor.
Built-In Swing Sensor

Built-in swing sensor is conveniently enabled and visible only when remote quality control operations such as calibration are being performed.
Compatible with RadiCS and RadiNET Pro versions 2.5.0 and later.
10-Bit Simultaneous Grayscale Display

10-bit (1,024 tones) from a 13-bit look-up table (8,161 tones) can be displayed simultaneously for high-definition medical imaging.
10-bit graphics board and 10-bit viewer software needed for 10-bit display.
Brightness Uniformity
The Digital Uniformity Equalizer (DUE) function provides optimum backlight luminance uniformity which is considered difficult to attain due to the characteristics of LCD monitors.
Calibration Mode Selection
Selectable with the front panel buttons, the CAL Switch function allows for various calibration modes of different modalities such as CR, CT, and endoscope images. Furthermore, auto mode settings can be made with the Auto CAL Switch function.
Brightness Stabilization
At startup or upon wakeup, the EIZO patented drift correction function quickly stabilizes the brightness level. In addition, a sensor measures the backlight brightness and compensates for brightness fluctuations caused by the ambient temperature and the passage of time.
This brightness stabilization function is EIZO patented technology (Japan patent number 3171808, US patent number 6188380).
Wide Viewing Angles
Wide Viewing angles with minimal color shift when viewed from the side.
Backlight Saver with Screen Saver
With ScreenManager Pro for Medical utility software installed, the Backlight Saver function turns off the monitor’s backlight when the screen saver is activated, and turns it on again when the computer comes out of screen saver mode. This function helps to reduce power consumption when the monitor is used for a prolonged period of time.
Backlight Saver with Viewer Application
By setting the Backlight Saver function to operate with viewer application, the monitor’s backlight is on while the viewer is being used and the backlight is off while the viewer is not being used.
Ergonomic Design
Narrow bezels require less eye movement in a multi-panel environment. The height and pivot adjustable stand offers added flexibility and viewing comfort.
Pairing Monitors
EIZO offers the same color and grayscale for two monitors bundled as a pair in one box.
LCD Panel Protector
This anti-reflective panel protector is pre-attached to the monitor at production for protection against dust and scratches.
Brightness Stability Within Usage Time Guaranteed
EIZO’s confidence in its product quality extends to brightness stability which is also covered during the usage time specified in the warranty.
Medical Standards
Compliance with stringent medical, safety, and EMC emissions standards including EN60601-1 and UL60601-1.
ISO 13485 Certification
Acquiring ISO 13485 certification demonstrates EIZO’s ability to consistently meet customer requirements for these devices and services.
5 Year Warranty
EIZO and its authorized distributors offer a five-year limited warranty.
| Cabinet Color | Black | |
|---|---|---|
| Panel | 54 cm (21.3") TFT Monochrome LCD Panel (IPS) | |
| Active Display Size (H x V) | 324.8 x 433.1 mm | |
| Viewable Image Size | Diagonal: 541 mm | |
| Native Resolution | 1536 x 2048 | |
| Pixel Pitch | 0.2115 x 0.2115 mm | |
| Grayscale Tones | 1,024 from a palette of 8,161 tones | |
| Viewing Angles (H, V) | 170°, 170° | |
| Brightness | 1000 cd/m2 (typical) | |
| Recommended Brightness for Calibration | 450 cd/m2 | |
| Contrast Ratio | 850:1 (typical) | |
| On/Off Response Time | 23 ms (typical) | |
| Scanning Frequency (H, V) | 31 - 100 kHz, 29.5 - 71.5 Hz (VGA Text: 69 - 71 Hz) Frame synchronous mode: 59 - 61 Hz |
|
| Dot Clock | 165 MHz | |
| Input Terminals | DVI-D 24 pin | |
| USB Ports | 1 upstream, 2 downstream | |
| USB Standard | Rev. 2.0 | |
| Power Requirements | AC 100 - 120 V, 200 - 240 V: 50 / 60 Hz | |
| Power Consumption / Save Mode | 115 W / Less than 3 W | |
| Sensor | Built-In Swing Sensor / Backlight Sensor | |
| Power Management | DVI DMPM | |
| OSD Languages | English, French, German, Italian, Japanese, Simplified Chinese, Spanish, Swedish, Traditional Chinese | |
| Net Weight (With Stand / Without Stand) | 10.8 kg / 7.8 kg | |
| Hole Spacing | VESA standard 100 x 100 mm | |
| Certifications and Standards | CE (Medical Device Directive), EN60601-1, UL60601-1, CSA C22.2 No. 601-1, IEC60601-1, VCCI-B, FCC-B, Canadian ICES-003-B, C-tick, FDA 510(k) *, RoHS | |
| Supplied Accessories | AC power cord, user's manual, signal cable (DVI-D ~ DVI-D), USB cable, EIZO LCD Utility Disk (RadiCS LE, ScreenManager Pro for Medical), ScreenCleaner, warranty card | |
| Warranty | Five Years |
| * Display of mammography images for diagnosis is not supported. |